Controller functions extension boards
ExtLeds board (extended indication)
Purpose
The ExtLeds board is designed specifically for CCU825 controllers and is intended to display extended information about the status of the controller.
Key features and specifications
- Indication: 16 inputs, 2 relays, 5 outputs, GSM signal strength, GSM network status, power availability
- Supported by CCU825 controllers
- Compatible with all types of enclosures
- Self-installation is possible
E01.1 board (16 inputs)
Purpose
The E01.1 board is designed specifically for the CCU825 controllers and adds 8 inputs, allowing to connect additional sensors. In this case, the total number of inputs is 16.
Key features and specifications
- Additional 8 inputs (16 in total)
- Supported by CCU825 controllers
- Compatible with all types of enclosures
- Self-installation is possible
E06 board (power ports extension)
Purpose
The E06 board is designed specifically for CCU825 controllers and is intended to solve the problem of the lack of power terminals when connecting a large number of sensors and actuators to the controller.
Key features and specifications
- Additional 5 power lines and 5 GND lines on the controller terminals
- Supported by CCU825 controllers
- Compatible with all types of enclosures
- Self-installation is possible
end faq
Miscellaneous
RTD-03.2 thermal sensor
Overall view of the RTD-03.2 thermal sensor (without enclosure)
Overall view of the RTD-03.2-INDR thermal sensor (indoor)
The enclosure of the indoor variant has additional openings on the front cover.
Overall view of the RTD-03.2-OUTDR thermal sensor (outdoor)
The enclosure of the outdoor variant has no additional openings.
Purpose
The RTD-03.2 thermal sensor is intended to measure ambient temperature and is designed specifically for CCU controllers.
Key features and specifications
- Measurement range: -40…+125°C
- Measurement error: ±2°С
- Measurement error after calibration: ±0.5°С
- Ability to calibrate with CCU controller
- Connects directly to CCU controller inputs
- Multiple sensors can be connected to the CCU controller simultaneously
- Three options: without enclosure, indoor, outdoor
- Supported by CCU825 controllers
RTD-04-PIPE thermal sensor
Purpose
The RTD-04-PIPE thermal sensor is designed in the form factor with the pipe mount and is intended to measure the in-pipe heat transfer fluid temperature.
Key features and specifications
- Measurement range: -30…+105°C
- Measurement error: ±1°С
- Connects directly to CCU controller inputs
- Multiple sensors can be connected to the CCU controller simultaneously
- Mounting on a pipe with the diameter of up to 18 mm using the standard clamp
- Mounting on a pipe with the diameter of up to 48 mm using a plastic clamp
- Supported by CCU825 controllers
RMA-04 active microphone
Purpose
The RMA-04 active microphone is intended to use as part of an external intercom and is designed specifically for CCU controllers.
Key features and specifications
- High sensitivity
- Built-in amplifier with 2 levels
- Connects to special CCU controller inputs
- Supported by CCU825 controllers
AR external whip GSM antenna
Purpose
The AR external whip GSM antenna is intended for CCU controllers installed in places with a sufficient GSM signal strength.
Key features and specifications
- Connector type: SMA
- Corner type, allows to turn along the body
- Compatible with CCU825 controllers
AE remote GSM antenna on cable
Purpose
The AE remote GSM antenna on cable is intended for CCU controllers installed in places with a weak GSM signal strength.
Key features and specifications
- Connector type: SMA
- Cable length: 2 m
- Glue layer for surface mounting
- Compatible with CCU825 controllers
Plug-in power supply unit
Purpose
The plug-in power supply unit is intended to power CCU controllers in the wall-mounted enclosure from an AC mains.
Key features and specifications
- Input: 100-240 V ~ 50/60 Hz
- Output: 15 V ⎓1 A
- Output short circuit protection
- Compatible with CCU825 controllers in the wall-mounted enclosure
Mean Well DR-15-15 DIN rail-mounted power supply unit
Purpose
The Mean Well DR-15-15 power supply unit is intended to power CCU controllers in the DIN rail-mounted enclosure from an AC mains.
Key features and specifications
- Input: 100-240 V ~ 50/60 Hz
- Output: 15 V ⎓1 A
- Output short circuit protection
- Compatible with CCU825 controllers in the DIN rail-mounted enclosure
- Temperature range: -20…+60°С
USB cable
Purpose
The USB cable (A/Mini-B) is intended to connect the CCU controller to a computer.